|
Whatman void
sealing (WVS) columns
Whatman void sealing (WVS) columns
Whatman WVS columns are renowned for their high quality, innovative
design and exceptional durability.
Features and Benefits
- Void sealing columns can last twice as long as
standard end fitting columns, saving as much as 50% on cost per test
- Available packed with spherical and irregular
media
- Integral void sealing mechanism prolongs
column life
- Reusable, hand tightened end-fittings save
money, allow for wrench-less installation and rapid column changes
- Require no holder or module, meaning fewer
components, reduced cost
Optimum Resolution
- Typical column efficiencies for:
- Partisil 10 µm media-45,000 N/m
- Partisil 5 µm media-65,000 N/m
- PartiSphere 5 µm media-90,000 N/m
Partisil® Irregular Media
Available in prepacked, replaceable columns and a choice of 5 µm and 10
µm phases. These include Silica, our popular ODS-3 and the other
reversed phase packings ODS-2 and C-8. Also available are SAX (Strong
Anion Exchanger), SCX (Strong Cation Exchanger) and PAC (Polar Amino
Cyano).
Due to the greater surface area of the irregular Partisil, the medium
offers enhanced selectivity and loading capacity. Through uniform
particle sizing, back pressure is minimized. Also, the neutral pH of
Partisil provides for better peak symmetry without the need for mobile
phase modifiers.
PartiSphere® Spherical Media
Available in prepacked columns and a choice of 5 µm high performance
phases. In addition to its efficient pure silica and monomeric C-18 and
C-8, Whatman has added WCX (Weak Cation Exchanger) as well as SAX, SCX
and PAC. PartiSphere media feature narrow particle size distribution and
excellent reproducibility.
PartiSphere WVS Columns: Engineered to Provide
Unsurpassed Consistency and Longevity
PartiSphere RTF
PartiSphere RTF (Reduced Tailing Factor) HPLC columns are
base-deactivated columns. They employ a unique proprietary process that
effectively "deactivates" the secondary chromatographic effect due to
residual silanols. In addition, these columns are extremely stable and
can be used from pH 2 to pH 8 with no loss in performance. Excellent for
separation of basic compounds without the need for amine-modified mobile
phases. PartiSphere RTF is available prepacked in Whatman Void Sealing
(WVS) and Analytical (WCS) column configurations and in a choice of
C-18, C-8 and cyano phases.
Features and Benefits
- All PartiSphere columns are guaranteed to perform reproducibly
every time, thanks to multiple quality control tests for both
primary and secondary separation mechanisms
- Polished internal column walls ensure packing symmetries and
efficiencies
- PartiSphere RTF (Reduced Tailing Factor) employs a unique
proprietary process that effectively "deactivates" the secondary
chromatographic effect due to residual silanols
HPLC Guard
Cartridge System
HPLC Guard Cartridge System
The prepacked, disposable plastic guard cartridge retains unwanted
materials that can harm your analytical column. Used in a wide range of
applications, the HPLC guard cartridge system offers high efficiency,
convenience and cost savings. The guard cartridge holder is available in
two configurations. The integral system attaches directly to and becomes
an integral part of the WVS replacement column requiring no connecting
tubing. Because of this, there is virtually no loss in efficiency.
The universal system can be used with any standard analytical column,
bringing guard cartridge convenience to traditional HPLC columns. Guard
cartridges are available in four phases: silica, reversed phase, anion
exchanger and cation exchanger.
Zero-Dead-Volume
Guard columns offer protection by trapping unwanted compounds that would
otherwise be strongly retained on the HPLC column. One of the problems
inherent with other guard columns is that they either contribute too
much dead volume or add to the analysis times of the separation
(especially in short, high speed columns). Whatman has overcome this by
developing a zero-dead-volume HPLC guard cartridge system which
eliminates almost all extra void volume and does not detrimentally
affect the separation.
| Typical Data |
| Partisil Bonded Phase |
Other Specifications |
| Silica |
Irregular. Pore Size 85Å |
| ODS-3 |
10.5% carbon load; end capped;
polymeric |
| ODS-2 |
16% carbon load; polymeric |
| C-8 |
8.5% carbon load; end capped; monomeric
brush |
| PAC |
0.85% N |
| SAX |
0.85% -NR5+ |
| SCX |
0.40% S |
| PartiSphere Bonded Phase |
| Silica |
Spherical. Pore Size 120Å |
| C-18 |
10% carbon load; end capped; brush |
| C-8 |
6% carbon load; end capped; brush |
| PAC |
0.85% N |
| SAX |
0.8% -NR3+ |
| SCX |
0.40% S |
| PartiSphere RTF Bonded
Phase |
| C-18 |
22% carbon load; monomeric brush |
| Ordering Information- WVS
Columns |
| Catalogue Number |
Particle Size (µm) |
Column Type |
Column Size (mm) |
| Partisil1 5 µm
& 10 µm Columns Only* |
| Partisil 5 Silica |
| 4681-1501 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| Partisil 5 ODS-3 |
| 4681-0502 |
5 |
Whatman Void Sealing |
4.6 x 125 |
| 4681-1502 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| Partisil 5 SAX |
| 4681-0505 |
5 |
Whatman Void Sealing |
4.6 x 125 |
| 4681-1505 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| Partisil 5 SCX |
| 4681-1507 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| Partisil 5 ODS-2 |
| 4681-1509 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| Partisil 10 ODS-3 |
| 4682-1502 |
10 |
Whatman Void Sealing |
4.6 x 250 |
| Partisil 10 SAX |
| 4682-1505 |
10 |
Whatman Void Sealing |
4.6 x 250 |
| Partisil 10 SCX |
| 4682-1507 |
10 |
Whatman Void Sealing |
4.6 x 250 |
| PartiSphere2 5
µm Columns* |
| PartiSphere Silica |
| 4621-0501 |
5 |
Whatman Void Sealing |
4.6 x 125 |
| 4621-1501 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| PartiSphere C-18 |
| 4621-0502 |
5 |
Whatman Void Sealing |
4.6 x 125 |
| 4621-1502 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| PartiSphere C-8 |
| 4621-0503 |
5 |
Whatman Void Sealing |
4.6 x 125 |
| PartiSphere SAX |
| 4621-0505 |
5 |
Whatman Void Sealing |
4.6 x 125 |
| 4621-1505 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| PartiSphere SCX |
| 4621-0507 |
5 |
Whatman Void Sealing |
4.6 x 125 |
| 4621-1507 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| PartiSphere PAC |
| 4621-0508 |
5 |
Whatman Void Sealing |
4.6 x 125 |
| 4621-1508 |
5 |
Whatman Void Sealing |
4.6 x 250 |
| Whatman Base-Deactivated
(WCS) HPLC Columns - PartiSphere2 5 µm RTF (Reduced
Tailing Factor) |
| PartiSphere RTF C-18 |
| 4522-0102 |
5 |
Standard Analytical |
4.6 x 250 |
| 4522-0202 |
5 |
Standard Analytical |
4.6 x 150 |
*Requires one-time purchase of 4.6 mm ID WVS end fittings, Catalogue
Number 4631-1001.
1Irregular Media
2 Spherical Media
| Ordering Information |
| Catalogue Number |
Product |
Quantity/Pack |
| |
| Guard Cartridge Holders
(For use with WVS Analytical Column) |
| 4631-1003 |
Integral Guard Cartridge Holder |
WVS Small 1 |
| 4631-1004 |
Universal Guard Cartridge Holder |
WCS Small 1 |
| Guard Cartridge System
Replacement Cartridges |
| 4641-0001 |
SIL Cartridge |
5 |
| 4641-0002 |
RP Cartridge |
5 |
| 4641-0005 |
SAX Cartridge |
5 |
| 4641-0007 |
SCX Cartridge |
5 |
| 4641-0008 |
PAC Cartridge |
5 |
| PartiSphere RTF Guard
Cartridges |
| 4641-1002 |
PartiSphere RTF C-18 |
5 |
| WVS Analytical Hardware |
| 4631-1001 |
Column end fittings: WVS type - (for
void sealing columns) |
1 pair |
|