Specifications:
The Bio-Cinerator sterilizer sterilizes microorganisms utilizing infrared heat produced by a ceramic core element. The ceramic element contains no asbestos and ensures maximum sterility without splatter across the work surface area. Complete sterilization occurs within 5-7 seconds at optimum sterilizing temperature of 1500oF (815.6oC). The small footprint makes the Bio-Cinerator sterilizer an ideal instrument for anaerobic and aerobic chambers alike. Several user friendly accessories are also available for the Bio-Cinerator sterilizer. Features: Sterilizes needles, loops, and culture tube mouths in five to seven seconds at optimum sterilizing temperature of 815.6oC (1500oF); Ceramic funnel tube enclosed in stainless-steel perforated guard and stainless-steel support stand; For AC220V 50/60Hz; Performance: The center high-temperature:815oC+ -50oC The Max-diameter of sterilizer goods: Dia 14mm The length of sterilizer:100mm Dimension:130W *102D * 180H Net weigh:1.3Kg
User Handbook Foreword Thank you for purchasing the Bio-Cinerator sterilizer. This user handbook includes a description of the functions and operating procedure of the instrument. To ensure that you use the instrument correctly, please read this handbook carefully before operating it. Please keep this handbook carefully, so that you can refer to it quickly in case you face any problems. First Inspection Upon first opening the instrument packing case, please check the instrument and add-ons against the enclosed packing list. If you discover anything wrong with the instrument or add-ons, or if some add-ons are missing, please contact the seller or manufacturer. Important Instructions 1 Important Safe Operation Information
Before safely operating the instrument, you need a complete understanding of how it works. Please read this handbook carefully before operating the instrument. 2 Safety When operating, maintaining and repairing this instrument, it is necessary to observe the following basic safety preventive measures. If these measures or the warnings pointed out in other parts of this handbook are not observed, it could influence the protection which this instrument provides and its anticipated areas of usage. Even when the instrument is set to a low heat level or when the power has just been switched off, its outer surface is still very hot. To avoid being scalded, do not touch it then.
3
Servicing the Instrument
4 After-Sales Service a) Maintenance contents The company will guarantee an exchange if, within one month of handing over the instrument, it breaks down due to flaws in its material and manufacturing. The company will guarantee repairs if, within 12 months of handing over the instrument, it breaks down due to flaws in its material and manufacturing. During the guaranteed repair period, the company will choose whether to repair or replace an instrument which has been proven flawed. The user has to send the instrument under guarantee to the servicing department determined by the company. The transport costs of sending the instrument to the servicing department will be borne by the user. The company will bear the transport costs of sending the instrument back to the user. As for repairs outside the guaranteed repair period, the company will collect an appropriate servicing fee.
b) Maintenance scope The abovementioned repair guarantee is not applicable when the instrument is damaged due to improper usage and maintenance, usage under conditions that do not conform to requirements, and servicing the instrument or replacing parts oneself without prior authorization. Catalogue
CHAPTER 1 SUMMARY -------------------------------------------------------- 1 TOC \o "1-1" \h \z 1.AREAS OF APPLICATION --------------------------------------------------- 1
2.NORMAL WORKING CONDITIONS -------------------------------------- 1
3.CHARACTERISTICS AND PERFORMANCE PARAMETERS ----- 1
CHAPTER 2 BASIC OPERATING INSTRUCTIONS -------------------- 3
1.STRUCTURE -------------------------------------------------------------------- 4
2.WORK PRINCIPLE ----------------------------------------------------------- 4
CHAPTER 3 OPERATING GUIDE ------------------------------------------- 5
1. PREPARATION ----------------------------------------------------------------- 5
2. USER GUIDE -------------------------------------------------------------------- 5
Chapter 1 Summary 1. Areas of application The Bio-Cinerator sterilizer is a high temperature sterilizing equipment commonly used in laboratories in Europe, America, and other developed countries. It is used to burn and sterilize platinum loops, vaccination needles, and other such small objects conveniently and quickly, completely taking the place of spirit lamps and Bunsen burners. The Bio-Cinerator sterilizer utilizes infrared heat to incinerate organic material deep within the ceramic funnel tube and prevents infectious spatter and cross contamination. Sterilization takes only 5 to 7 seconds at optimum sterilizing temperature of 825°C. This unit can be used in anaerobic chambers. It can even be used in the wilderness, allowing you to sterilize and burn any time.
2. Normal working conditions Environmental temperature: -10°C ~ 50°C Relative humidity: ≤90% Power source: AC220V ± 22V 50Hz ± 1Hz Highest altitude above sea level: Unlimited
3. Product characteristics and performance parameters 3.1 Product characteristics Small in size, light weight, simple and convenient to operate; main body made entirely of stainless steel; aesthetically pleasing, easy to clean, long working life. 3.2 Performance parameters Model number: Bio-Cinerator IV Highest temperature at core: 825°C ± 50°C Largest possible diameter of item to be sterilized: φ14mm Length of heating area: 100mm External dimensions: Length x width x height = 130 x 102 x 180mm Power source: AC220V ± 22V 50Hz ± 1Hz 135W Weight: 1.3kg Chapter 2 Basic Operating Instructions This chapter introduces the structure of this instrument, its on-off functions, and the preparations that need to be done before turning it on. If using this instrument for the first time, familiarize yourself with the contents of this chapter before turning on the instrument.
1. Structure
Structure details: 1. Heating module 2. Supporting column 3. Box 4. High/low temperature indicator light (red: very hot; green: low heat) 5. Power source and temperature control switch (“up” position: very hot; “middle” position: power off; “down” position: low heat) 6. Fuse
2.Work Principle The Bio-Cinerator sterilizer uses electronic control to heat up the infrared heating elements, thereby reaching the required temperature. This instrument provides two levels of temperature to choose from. During normal work, the user should choose the high heat level. At this time, the red indicator light for high heat level will start to glow. The instrument will take about 15 ~ 20 minutes to reach the required temperature. If the instrument is temporarily not in use, the temperature can be set to low heat, and the green indicator light for low heat level will start to glow. The instrument is then in preheat mode. If the instrument is unused for a long time, turn off the power by putting the power switch (No. 5 in the above diagram) in the middle position. Chapter 3 Operating Guide 1. Preparation Place the instrument steadily on the work table, taking special care to ensure that there are no flammable or explosive items around. After that, put the power switch in the middle position, thus turning off the instrument. Insert the power plug into an AC220V power socket with good grounding.
2. User guide When using the instrument, set the power switch to the high heat level. At this time, the red indicator light for high heat level will start to glow. Wait 15 ~ 20 minutes for the temperature within the small radiation holes to reach the required level. Note 1: If using the instrument for the first time, the small radiation holes will emit white smoke after the instrument is connected to the power source. This is because the high temperature protective layer of new products contains glue, fat and evaporating moisture. The smoke is not due to the instrument breaking down and will disappear after the instrument has been in use for a few minutes. Please do not be too concerned about this. Place the loops, needles, and other similar objects into the high temperature area within the heating holes to undergo sterilization. (The centre portion of the heating body is the hottest.) If the instrument will not be used for a short period of time, set the switch to the low heat position. The green indicator light for low heat level will start glowing. The instrument is in the preheat and energy conservation mode. When ready to sterilize, set the switch to the high temperature position to immediately begin sterilizing. If the instrument will not be used for a long period of time, the power should be turned off, to lengthen the working life of the heating body and to save energy. Note 2: Do not heat vaccination needles or other metal vaccination items for too long, in order to prevent scalding. To prevent electric shock, do not place metal items into the interior of the electric appliance (other than the heating holes). Note 3: The suggested voltage for this instrument is between 220 ~ 240V. Under such conditions, the instrument can reach the required sterilizing temperature more quickly, and sterilize more quickly as well. The instrument can also operate on a voltage lower than 220V, but it will take slightly longer to reach the required sterilizing temperature. This is not due to the instrument breaking down. It will take 5 ~ 7 seconds to reach requirements if loops, needles, and so on, are placed deep within the heating holes. The resting time need not be long, because all microorganisms will be killed within 5 seconds. Microorganism culture tubes made of glass and with a diameter smaller than 14mm can also be sterilized within the heating holes. At this time, take special care to ensure that the tubes do not contain any liquid or other objects, to prevent the liquid splashing out, and explosions or other dangerous accidents from happening. Note 4: Do not place plastic and other materials which cannot withstand high temperatures into the heating holes, in order to prevent accidents. Note 5: The instrument can work continuously, but it is suggested that the user not let it run for long periods in the high temperature setting, because this can influence the working life of the instrument. Do not leave it on for long periods of time unattended, to prevent fires and other such accidents.
|
|
© 2005 GENTAUR bvba |